Quick Verdict

Vaillant aroTHERM plus is the more efficient choice on its MCS-certified figures, with lower estimated running costs, while Mitsubishi Electric Ecodan is more budget-friendly with pre-grant pricing from £9,000 (the £7,500 grant applies equally to both in England and Wales), while Mitsubishi Electric Ecodan has the longer standard warranty (3 yr (up to 7)).

Get 3 free quotes for Mitsubishi Electric Ecodan or Vaillant aroTHERM plusFrom local MCS-certified installers. Takes 60 seconds, no obligation.

Side-by-Side Comparison

FeatureMitsubishi Electric EcodanVaillant aroTHERM plus
Installed price (before grant)£9,000 - £14,000Lower£10,000 - £16,000
After £7,500 grant (illustrative, England and Wales)£1,500 - £6,500£2,500 - £8,500
SCOP at 35°C (MCS)4.624.88Higher
SCOP at 55°C (MCS)3.513.63Higher
Largest size10kW12kWLarger homes
Standard warranty3 yearsLonger2 years
Longest warranty (conditions apply)7 years7 years
Sound power (declared)54 dB(A)Lower55 dB(A)
Annual running cost (est., 45°C flow)~£650/yr~£620/yrLower
Refrigerant and max flowR290, up to 75°C flowR290, up to 75°C flow
CountryJapan / UKGermany
UK brandYesNo
Best forHomes keeping their existing radiators, from a UK-built rangeEfficiency-first buyers who want a proven, widely monitored unit

Specifications and pricing are indicative for the UK market as at June 2026. Post-grant figures illustrate the £7,500 Boiler Upgrade Scheme in England and Wales (Scotland uses the Home Energy Scotland grant and loan; Northern Ireland has no equivalent). Running costs assume ~10,000 kWh of heat a year at 26.32p/kWh (Ofgem cap average, October to December 2026; changes quarterly). Confirm current models and exact pricing with your MCS-certified installer.

Model by Model, Size for Size

Each Mitsubishi Electric Ecodan model against the nearest Vaillant aroTHERM plus size. Better figure in green.

8.5 kW vs 7 kWEcodan R290 8.5kWR290 · PUZ-WZ85VAAaroTHERM plus 7kWR290 · VWL 75/6 A 230V S2
SCOP at 35°C (MCS)4.474.36
SCOP at 55°C (MCS)3.513.39
Sound power (declared)54 dB(A)55 dB(A)
Maximum flow temperature75°C75°C
Running cost (est.)~£660/yr~£680/yr
Installed price from (before grant)£9,000£10,000
Outdoor unit weight103 kg128 kg
Suits3-4 bed semi or detached3 bed semis and well-insulated homes
10 kW vs 12 kWEcodan R290 10kWR290 · PUZ-WZ100VAAaroTHERM plus 12kWR290 · VWL 125/6 A 230V S2
SCOP at 35°C (MCS)4.624.88
SCOP at 55°C (MCS)3.483.63
Sound power (declared)55 dB(A)60 dB(A)
Maximum flow temperature75°C75°C
Running cost (est.)~£650/yr~£620/yr
Installed price from (before grant)£10,000£11,000
Outdoor unit weight120 kg194 kg
Suitslarger or older detached homeslarge detached homes

Sizes are the makers' labels; where a label is not the rated output, the brand page says what is. Prices are PumpSwap's indicative estimates. Running costs use the same basis as the table above.

Price Comparison

Mitsubishi Electric Ecodan starts from £9,000 installed before any support (indicative, June 2026), while Vaillant aroTHERM plus starts from £10,000. That is a difference of roughly £1,000 at the entry level. Mitsubishi Electric Ecodan is the more budget-friendly option upfront, though Vaillant aroTHERM plus may claw some of that back through running costs over time. Both are installed prices in GBP with 0% VAT (until 31 March 2027) already applied. In England and Wales the £7,500 Boiler Upgrade Scheme grant comes off both equally, so the pre-grant difference carries straight through: illustratively £1,500 - £6,500 for Mitsubishi Electric Ecodan and £2,500 - £8,500 for Vaillant aroTHERM plus out of pocket. Your MCS-certified installer claims the grant for you.

Efficiency Comparison

SCOP (seasonal coefficient of performance) is the key efficiency measure for a heating heat pump: the kilowatt-hours of heat you get per kilowatt-hour of electricity across a whole heating season. The figures here are MCS-certified, at 35°C flow (underfloor heating or large radiators) and 55°C (hotter radiators). Mitsubishi Electric Ecodan is certified at 4.62 at 35°C and 3.51 at 55°C, while Vaillant aroTHERM plus is certified at 4.88 and 3.63. On our estimates at a 45°C design flow temperature, the Vaillant aroTHERM plus costs about £30 a year less to run at Ofgem cap electricity prices, or approximately £300 over ten years. Real-world efficiency depends heavily on system design and flow temperature, which is what the MCS heat loss survey is for.

Warranty Comparison

Mitsubishi Electric Ecodan: 3 years as standard; 5 years through an Accredited Ecodan Installer and 7 through a Heating Business Solutions Partner. Register within 30 days of commissioning or cover drops to 12 months. Cylinders get 3 years at every tier. Vaillant aroTHERM plus: 2 years as standard; up to 7 years with a Vaillant cylinder through a Platinum, Renewable Partner or myREWARDS installer. Register within 30 days and service annually. On standard terms, the Mitsubishi Electric Ecodan has the longer cover; the longer terms on either side depend on registration, servicing and the installer. Workmanship cover for the installation itself comes separately from your installer and should be in writing.

Noise Comparison

Noise matters in UK homes because the outdoor unit often sits close to a neighbour's boundary or a bedroom window. The like-for-like figure is the maker's declared sound power: the noise the unit itself emits. Mitsubishi Electric Ecodan: 54 dB(A). Vaillant aroTHERM plus: 55 dB(A). On paper the Mitsubishi Electric Ecodan is quieter by 1 dB(A). What a neighbour hears is much lower and falls with distance, and permitted development rules require the installation to meet the MCS noise standard at their window, so siting matters as much as the unit.

Cold-Weather and Retrofit Suitability

Two things decide how well a unit suits an older UK home: cold-weather output and flow temperature. Mitsubishi Electric Ecodan uses R290 refrigerant (up to 75°C flow), while Vaillant aroTHERM plus uses R290 (up to 75°C flow). Both reach 70°C or more, so both can work with existing radiators; the decision comes down to price, warranty and installer availability. Modern units hold useful output well below freezing. In the colder parts of the UK (Scotland and northern England in particular), frosty mornings trigger short defrost cycles that trim efficiency, so ask each installer for low-temperature output figures and take the MCS heat loss survey seriously; radiator upsizing is more commonly recommended there so the system can run at efficient flow temperatures.

Pros and Cons

Mitsubishi Electric Ecodan

Pros

  • Made in Livingston, Scotland
  • R290 range reaches 75°C flow, so existing radiators can often stay
  • Quiet Mark certified (R290 8.5, 10 and 12 kW)
  • The 8.5, 10 and 12 kW sizes all come in single phase

Cons

  • Standard warranty is 3 years; 7 needs a top-tier Mitsubishi installer
  • Single-phase 10 and 12 kW units need a dedicated 32 A or 40 A supply

Vaillant aroTHERM plus

Pros

  • Natural R290 refrigerant, up to 75°C flow
  • Quiet Mark certified (except the 10 kW)
  • Among the best measured real-world efficiency on heatpumpmonitor.org (median 4.06)

Cons

  • Standard warranty is 2 years; 7 needs a Vaillant cylinder and a partner installer
  • The /6 range is being replaced by a new model launched in June 2026
  • The 12kW outdoor unit is tall (1,565 mm) and heavy (194 kg)

Which Should You Choose?

Choose Mitsubishi Electric Ecodan if...

  • You want a lower upfront cost (from £9,000 vs £10,000 before the grant)
  • You want a longer standard warranty (3 yr (up to 7) vs 2 yr (up to 7))
  • A lower declared sound power matters to you (54 vs 55 dB(A))
  • You want a UK brand with local manufacturing or headquarters behind it

Choose Vaillant aroTHERM plus if...

  • You want the higher certified efficiency (SCOP 4.88 vs 4.62 at 35°C, MCS)
  • You want lower estimated annual running costs (~£620/yr vs ~£650/yr)

The grant is the same, whichever brand you pick

Every air-to-water unit on this page qualifies for the £7,500 Boiler Upgrade Scheme grant in England and Wales (£9,000 for oil and LPG heated homes until March 2027) when fitted by an MCS-certified installer, who claims it on your behalf so it comes straight off the quote. Scotland uses the Home Energy Scotland grant of up to £7,500 (£9,000 rural and island) plus an optional interest-free loan; Northern Ireland currently has no equivalent scheme. 0% VAT on residential installations applies UK-wide until 31 March 2027. Accurate as at July 2026.